Inner Range

The One Door Access module is an economical one door, one card reader access module.

Flexibility Plus
Configuration options allow for a broad range of card reader technologies.

 

Connectivity

The 1 Door Access Module is connected directly to the Concept RS485 LAN. Up to 99 of the 1 Door Access modules may be installed in a single panel system.

 
 
  • One door, one reader access control module
 

Enterprise Level Access Control

The One Door Access module fully supports the advanced Concept access control features: i.e. soft / hard / timed anti-passback, dual user, card and PIN, free access via timezones etc. read more.

Features:

  • Supports magnetic swipe or Wiegand card readers without the need for an additional interface
  • Standard version supports offline database of up to 31 backup cards
  • Provides reed and tongue sense monitoring
  • Request to Enter (REN) and Request to Exit (REX) inputs provided
  • Door Open Too Long (DOTL), valid and invalid outputs
  • On-board lock relay
  • Fuse protection of Reader head power

Download data sheet

Physical  
PCB Dimensions 95(L) x 95(W) (mm)
Installation Environment 0°C - 40°C @15 - 85% Relative humidity (non-condensing)
Electrical  
Input Voltage to PCB 11-14VDC
Operational Current 15mA
Max 25mA with lock relay active. (NOT including Reader or Auxiliary Out current)
Fuse Protection 500mA
Inputs  
Zone Inputs 4 (May have predefined functions depending on programming options selected, i.e.: Door Reed, REX, REN, Tongue Sense and Arm button)
Reader Ports 1
Outputs  
Relay 1 (Typically used for door locks)
Physical Auxiliaries 1 (Typically used for Valid/Invalid indication)