Inner Range

The Mini Expander module provides a cost effective solution whenever a small number of Zones and Auxiliaries are required.

The Mini Expander module is available in both powered or unpowered forms. The powered Mini Expander module (995086PS) is supplied in a larger cabinet and comes complete with a 2 Amp DC power supply with battery recharging circuitry.

Features:

  • 8 zone inputs
  • 8 auxiliary outputs
  • Supplied in a plastic utility enclosure for easy mounting
  • Programmable input de-bounce time
  • Event counting facility
  • Supplied in a metal enclosure or plastic utility enclosure for easy mounting

Download Mini Expander data sheet
Download Expander Module Options data sheet

 

Exclusive Features

The Mini Expander module has a programmable de-bounce feature for increased sensitivity to inputs such as hold-up buttons, event counting and monitoring of electronic plant equipment. The input counting feature enables accurate monitoring of events and/or customer activity.

 

 

Connectivity

The mini expander is connected directly to the Concept RS485 LAN. Up to 99 mini expanders may be installed in a system comprising a single Concept 4000 Control Module panel.

 

 

 

 

 

Physical  
Cabinet Dimensions (Unpowered Version) 305(L) x 140(W) x 72(D) (mm)
Cabinet Dimensions (Powered Version) 252(L) x 358(W) x 85(D) (mm)
PCB Dimensions 140(L) x 95(W) (mm)
Installation Environment 0°-40°C @ 15% to 85% Relative humidity (non-condensing)
Cabinet Battery Bracket To suit 12V 7AH Sealed Lead Acid battery
Electrical    PCB Versions    Transformer Versions
Mains Input Voltage N/A 240VAC, 50Hz
Mains Input Current N/A 500mA
Input Voltage to PCB 11-14VDC 16-18VAC
Current Consumption  
Total Current Limit N/A 2.0A
Operational Current
(No peripherals connected)
  30mA   30mA
Recommended allowance for battery charging   N/A   300mA
Available Current (for relays, detectors, auxiliaries , etc.)   Power Supply source   dependent   1.6A
Inputs  
Zone Inputs 8
Programmable Input De-bounce 5mS to 1250mS, programmable per zone input
Outputs  
Outputs (open collector) 8
Max. switchable current per Auxiliary Aux.1:500mA, Aux.2-8:200mA

Relays Expandable to 8 with optional 8 Relay Expander Board 995082E - replaces on-board Auxiliaries